Open Research Index

Optimal Placement of Docking Stations and Resident AUVs for Subsea Pipeline Inspection

Gabrielė Kasparavičiūtė, Pasquale Grippa, Kjetil Skaugset, Asgeir J. Sørensen, Martin Ludvigsen

arXivarxiv/2607.19944Jul 22, 2026math.OCscore 0

A two-stage mixed-integer linear programming framework is introduced for subsea pipeline incident response planning, jointly optimizing Subsea Docking Plate (SDP) placement and resident autonomous underwater vehicle allocation to minimize both maximum and average response times under spatial uncertainty. Phase 1 minimizes the maximum response time across all potential leak locations. Phase 2 reduces the average response time subject to the maximum bound. A case study based on the Johan Sverdrup oil and gas field in Norway, with 9 SDP options and 33 pipelines, shows that just a few…