Extreme-ultraviolet spectroscopy using quantum logic: a feasibility study for the 1S-2S transition in singly-ionized helium
Extreme-ultraviolet (XUV) spectroscopy represents an important new direction in precision physics, with potential applications ranging from the metrology of fundamental constants to tests of physics beyond the Standard Model. However, the application of quantum control methods for precision spectroscopy remains an open challenge in the XUV range. Here we present a novel quantum logic (QL) spectroscopy method for precision spectroscopy of weak XUV transitions, and numerically validate its feasibility for the $1S-2S$ transition at 40.81\,eV in singly-ionized helium (He$^{+}$). We propose a…