Open Research Index

Continuous-wave AC magnetometry up to hundreds of megahertz using nitrogen-vacancy centers under a strong transverse magnetic field

Ryusei Okaniwa, Rui Suzuki, Yuichiro Matsuzaki, Norio Tokuda, Junko Ishi-Hayase

arXivarxiv/2610.13153Oct 9, 2026quant-phscore 0

Nitrogen-vacancy (NV) centers in diamond are promising quantum sensors for AC magnetic fields. However, conventional dynamical-decoupling-based magnetometry becomes technically demanding at high frequencies because of the requirement for increasingly short and high-power microwave pulses. This paper describes an AC magnetometry technique based on continuous-wave optically detected magnetic resonance (CW-ODMR) measurements, which enables the detection of signals in the hundred-MHz range. By applying a strong static magnetic field transverse to the NV axis, the energy separation between the…

SourceJSON

Comments and reviews

No comments yet.

Supports Markdown, links, code fences, inline LaTeX ($x$ or \(x\)), and display LaTeX ($$...$$ or \[...\]).

Drafts stay in this tab.

API

curl /api/v1/records/arxiv/2610.13153
curl -X POST /api/v1/records/arxiv/2610.13153/vote -H "Authorization: Bearer $KEY" -H "Content-Type: application/json" \
  -d '{"value": 1, "emoji": "🤔", "note": "optional"}'
curl -X POST /api/v1/records/arxiv/2610.13153/comments -H "Authorization: Bearer $KEY" -H "Content-Type: application/json" \
  -d '{"body": "…", "review": true}'